On 18 September 2025, Kavaken flagged the generator non-drive-end (NDE) bearing temperature of a wind turbine. It was running 15.5% above its expected range and 23.5% above the average of similar turbines in the same wind farm, with a consistent deviation and an increasing trend. SCADA showed no warning, and by SCADA's standards the temperatures were normal. Kavaken recommended checking the automatic lubrication and flushing the bearing. Following the flag, the turbine was inspected and the need for flushing was confirmed. The OEM flushed the bearing on 10 February 2026, and the positive effect was visible in the signals the next day.

Why flushing was the recommendation
The deviation was not a spike. The NDE bearing temperature stayed above its expected range at a consistent level, and the trend was rising.
On the same turbine type, similar cases were most often resolved by cleaning the bearing lubrication channels, the chimneys and the waste oil reservoir. Kavaken therefore recommended two steps: check the automatic lubrication mechanism and maintain it if needed, and flush the bearing.
146 days, step by step
KavakenSite teamOEMSignal
- Day 0 · 18 Sep 2025 · Kavaken
Kavaken flags NDE bearing overheating
The generator NDE bearing temperature was running 15.5% above its expected range and 23.5% above the average of similar turbines in the wind farm. The deviation was consistent and the trend was rising. Kavaken recommended an automatic lubrication check and bearing flushing.
- Day 77 · 4 Dec 2025 · Site team
Client asks the OEM to investigate
The client passed the flag to the OEM for inspection.
Flag log, site team (translated): The OEM was informed so that it could investigate.
- Day 145 · 10 Feb 2026 · OEM · Fix
OEM flushes the bearing
The OEM carried out a bearing flushing and completed its checks.
Flag log, site team (translated): Flushing was performed by the OEM, and checks were completed.
- Day 146 · 11 Feb 2026 · Signal
Signals show the effect of flushing
One day after the flushing, the positive effect of the intervention was visible in the bearing temperature signals.
- Day 146 · 11 Feb 2026 · Site team
Flag resolved, flushing need confirmed
The client closed the flag. There had been no SCADA warning, and SCADA showed the temperatures as normal. The turbine was climbed at the client's request because of the Kavaken flag, and the inspection showed that flushing was needed.
Flag log, site team (translated): There was no SCADA warning; according to SCADA, the temperatures were at a normal level. Following the Kavaken flag, the turbine was climbed on request, and the need for flushing was seen.
Why it stayed hidden
The bearing never crossed a SCADA limit. SCADA raised no warning, and by its standards the temperatures were normal. The issue only became visible when the temperature was compared with the bearing's own expected range and with similar turbines in the same wind farm: 15.5% above the first and 23.5% above the second. Without the flag, nothing in routine monitoring called for a climb.
The outcome
The need for the work was confirmed on the turbine: the inspection carried out because of the Kavaken flag showed that the bearing needed flushing. The OEM flushed it on 10 February 2026, and the positive effect of the intervention showed in the signals the following day.
The client rated Kavaken's role as helpful.
- Production
- 160 MWh
- Financial
- USD 10,500
- CO2
- 100 t
Avoided-loss potential: Kavaken's estimate of the loss that the early finding prevented. It is not a realized saving.
Takeaway
A bearing can stay inside SCADA limits and still run well above its own expected range and its neighbours. Comparing each turbine with its expected behaviour and with similar turbines on the same site catches a lubrication problem before a limit does.