    New bypass valve, same heat: a stuck contactor in the oil-cooler fan circuit

    Gearbox oil ran 6.9% above expected three days after the thermostatic bypass valve had been replaced. The usual fix was already done, so the issue looked handled. A stuck contactor in the oil-cooler fan circuit, replaced on 3 July 2026, ended it.

    Wind530MWhavoided-loss potential
    +6.9%
    sump and inlet oil above expected
    +10.8%
    above similar turbines
    2 days
    from flag to contactor replacement
    2 stops
    low gear inlet oil pressure, 2 July

    Kavaken flagged a wind turbine gearbox on 1 July 2026. The sump and gear inlet oil temperatures ran 6.9% above expected and 10.8% above similar turbines. It was the second flag in a week. After the first, on 26 June, the site team replaced the thermostatic bypass valve on 28 June, before any SCADA warning. The temperatures did not improve. Kavaken read the bearing data as a cooling problem across the whole oil circuit and pointed to the oil-cooler fans. On 3 July the site team found a stuck contactor in the fan circuit and replaced it. Oil and bearing temperatures improved suddenly, and on 6 August the client wrote that the problem was solved.

    Why Kavaken looked past the gears

    The gearbox bearing temperatures were rising together with the oil temperatures. But the difference between bearing and oil temperatures was not higher than at similar wind farms, and on most days it was lower. That pattern points away from local friction at a gear or a bearing. It points to the whole oil circuit not shedding enough heat.

    Kavaken recommended checking the oil-cooler fans on a windless day: reverse airflow, low flow rate, or the two fan stages failing to engage. It also recommended checking whether the newly replaced thermostatic bypass valve could be stuck.

    Diagram of a gearbox lubrication and cooling system: gearbox, pump and filter, thermostatic bypass valve, oil-air cooler with fan motor, and an electrical cabinet with the contactor, above seven numbered steps of the case.
    Figure 1. The gearbox oil runs from the pump and filter through the thermostatic bypass valve to the oil-air cooler. The fault sat in the electrical circuit of the cooler fan, not in the oil path.

    Two flags, one stuck contactor

    SignalKavakenSite team

    1. Day −2 · 29 Jun 2026 · Signal

      First SCADA oil temperature warning

      Kavaken had flagged the sump oil temperature on 26 June, about 7.7% above expected. The site team replaced the thermostatic bypass valve on 28 June. One day later, the first SCADA warning on oil temperature came in.

      Flag log, Kavaken (translated): After the thermo bypass change on 28 June, the oil temperature warning also came on 29 June.

    2. Day 0 · 1 Jul 2026 · Kavaken

      Kavaken flags the oil temperatures again

      GBX OilTemp Sump and GBX OilTemp GearInlt ran 6.9% above expected and 10.8% above the average of similar turbines, with a steady, flat trend. Kavaken pointed to the oil-cooler fans and the new bypass valve.

    3. Day 1 to 2 · 2 Jul – 3 Jul 2026 · Signal

      Stops and high temperature warnings

      The turbine stopped twice on low gear inlet oil pressure, for 0.65 and 0.3 hours. A high sump oil temperature warning lasted 13.97 hours, and a high gear inlet oil temperature warning followed for 6.42 hours.

    4. Day 2 · 3 Jul 2026 · Site team · Fix

      Stuck fan contactor found and replaced

      The site team inspected the oil-cooler fan circuit, found a stuck contactor and replaced it.

      Flag log, site team (translated): Contactor sticking was detected on 03/07/2026. The part was replaced. Monitoring should follow.

      Close-up of two identical contactors in a cabinet. The left one, marked as stuck, has dark arc and soot marks on its pole windows; the right one, marked as a healthy reference, has clean windows.
      Figure 2. The stuck fan contactor shows arc and soot marks on its pole windows. The contactor of the same type next to it has clean windows.
    5. Day 35 · 5 Aug 2026 · Kavaken

      Kavaken confirms a sudden improvement

      After a month of monitoring, Kavaken confirmed that the sump and inlet oil temperatures and the gearbox high-speed shaft bearing temperature had improved suddenly after the 3 July intervention.

      Flag log, Kavaken (translated): The intervention on 3 July was successful. It caused a sudden improvement in the sump and inlet oil temperatures and the gearbox HSS bearing temperature that this flag is about.

    6. Day 36 · 6 Aug 2026 · Site team

      Client reports the problem solved

      The client confirmed the result and the case was resolved.

      Flag log, site team (translated): The problem has been solved.

    7. 17 Oct 2026 · Site team

      Photo confirms which contactor stuck

      From a site photo, Kavaken identified the stuck contactor by the arc and soot marks on its pole windows, which a neighbouring contactor of the same type did not have. The client confirmed the identification.

    Why it stayed hidden

    28 June
    bypass valve replaced, before any SCADA warning
    29 June
    first SCADA oil temperature warning
    Normal
    bearing-to-oil temperature gap versus similar farms

    The first action came before SCADA raised anything: the site team replaced the thermostatic bypass valve on 28 June on Kavaken's first flag, and the first oil temperature warning only came on 29 June. With the usual fix already done, the issue looked handled. The bearing-to-oil temperature gap gave no sign of a worn gear or bearing. The cause sat outside the gearbox, in the electrical circuit of the cooler fans.

    The outcome

    Kavaken confirmed the result in the data: after the contactor replacement on 3 July, the sump and inlet oil temperatures and the gearbox high-speed shaft bearing temperature improved suddenly. On 6 August the client wrote that the problem was solved.

    A site photo later showed arc and soot marks on the pole windows of the replaced contactor, and clean windows on the same type of contactor next to it. The client confirmed that this was the contactor that had stuck.

    The client rated Kavaken's role in the resolution as key.

    Production
    530 MWh
    Financial
    USD 27,600
    CO2
    330 t

    Avoided-loss potential: Kavaken's estimate of the loss that the early finding prevented. It is not a realized saving.

    Takeaway

    When a new bypass valve does not bring gearbox oil temperatures down and the bearing-to-oil gap looks normal, check the cooler fan circuit, contactors included, before the gearbox itself.

    Next caseGenerator ran 40.5% hotter than its neighbours while the weather cooledRead the case →
    Kavaken

    Autonomous Asset Performance Managementfor Renewable Energy

    Monthly updates from Kavaken. Unsubscribe anytime.

    United Kingdom

    Kavaken Limited

    TUSPark Eagle Labs
    27 Grainger Street
    Newcastle, NE1 5JE

    United States

    Kavaken, Inc.

    2500 Yale St Ste B
    Houston, TX 77008

    Türkiye

    Kavaken Yazılım A.Ş.

    Resitpasa Mah. Katar Cad.
    ITU ARI 8, 2/11
    Istanbul, 34467

    Member of:
    ORE CatapultNOFGWECTÜREBAmerican Clean Power
    Find us at:
    LinkedInYouTube

    © 2026 Kavaken. All rights reserved.