In early April 2024, Kavaken flagged anomalous behavior in the main shaft bearing heat characteristics of a client's wind turbine. The anomaly was on a rising trend. In January 2025 there was still no CMS or SCADA warning. A SCADA temperature warning came by May 2025. A CMS ticket came only in October 2025, about 18 months after the flag. The site team extended the lubrication interval in May 2025. The effect showed in the signals but did not stop the trend. The main bearing was replaced on 23 August 2026, and the signals stayed normal afterwards.
Kavaken and the CMS, on the same bearing
Two systems watched the same main shaft bearing. They raised the issue at very different times.
Between the two, in January 2025, there was no CMS or SCADA warning. Kavaken had already raised the risk level and recommended a check of the main bearing lubrication systems.

From the first flag to the bearing replacement, step by step
KavakenSite teamSignal
- Day 0 · 5 Apr 2024 · Kavaken
Main bearing temperature anomaly flagged
Kavaken detected anomalous behavior in the main shaft bearing heat characteristics. When the flag was opened on 21 May 2024, the anomaly was still on a rising trend.
Flag log, Kavaken (translated): From early April 2024, an anomaly related to the main bearing temperatures began to show. It is still on a rising trend.
- Day 285 · 15 Jan 2025 · Kavaken
Risk level raised, still no warning
The anomaly on the DTR RotBearTemp 1 sensor increased, and Kavaken raised the risk to level 2. On 16 January there was no CMS or SCADA warning.
Flag log, Kavaken (translated): Currently there is no CMS or SCADA warning.
- Day 313 · 12 Feb 2025 · Kavaken
Lubrication system check recommended
The trend was still upward. Kavaken recommended checking the main bearing lubrication systems, together with another turbine. The site team started investigating on 20 February.
- Day 398 · 8 May 2025 · Site team · Fix 1 of 2
Lubrication interval extended after SCADA warning
After a SCADA temperature warning with a set value of 50 °C, the site team changed a lubrication parameter and extended the lubrication interval.
Flag log, site team (translated): After the temperature warning on SCADA (warning set value: 50 degrees), the lubrication parameter was changed on 08/05/2025 and the lubrication interval was extended.
- Day 447 · 26 Jun 2025 · Kavaken
Anomaly back on a rising trend
On 22 May the effects of the intervention were visible in the signals, and the turbine was moved to monitoring. By 26 June the anomaly was rising again. Kavaken recommended evaluating it together with another turbine on site that showed a similar trend.
- Day 566 · 23 Oct 2025 · Signal
CMS ticket in place
A CMS ticket was in place for the bearing, and a replacement was under consideration.
- Day 678 · 12 Feb 2026 · Signal
Stop on high rotor bearing temperature
The turbine stopped on a high rotor bearing temperature stop (ROTB Temp H Stop).
- Day 821 to 867 · 5 Jul – 20 Aug 2026 · Signal
Repeated warnings, then stops and limitation
The turbine had long stops caused by blade damage. When it restarted, the bearing temperature anomaly continued where it had left off. Eight DTR RotBearTemp 1 H Warn warnings followed between 5 July and 14 August, the longest lasting 100.1 hours. By 20 August, Kavaken saw a performance drop, stops and limitation caused by the main bearing.
Flag log, Kavaken (translated): When the turbine was restarted, the main bearing temperature anomaly continued where it had left off.

Figure 2. Eight DTR RotBearTemp 1 high-temperature SCADA warnings between 5 July and 14 August 2026, the longest lasting 100.1 hours, each with 0 kWh recorded loss. - Day 870 · 23 Aug 2026 · Site team · Fix 2 of 2
Main bearing replaced
The main bearing was replaced.
Flag log, site team (translated): 23/08 main bearing replacement.
- Day 910 · 2 Oct 2026 · Kavaken
Values normal after replacement, flag resolved
On 17 September, Kavaken saw that the signals had been normal for close to a month after the replacement. The flag was resolved on 2 October, with values normal after the replacement.
Why it stayed hidden
The issue was a change in how the bearing heats up, not a single high reading. The SCADA warning trips at a fixed 50 °C. A slow drift stays below that limit for months, especially in cooler weather. Kavaken compares the main shaft bearing temperature with inputs such as the nacelle air temperature, so the drift showed from April 2024. In January 2025 neither CMS nor SCADA had raised anything. The first SCADA temperature warning came by May 2025, and the CMS ticket in October 2025.
The outcome
The main bearing was replaced on 23 August 2026. By 17 September the signals had been normal for close to a month. On 2 October the values were still normal after the replacement, and the flag was resolved.
The earlier lubrication change of May 2025 showed in the signals, but the anomaly was on a rising trend again by June 2025. Before the replacement, the bearing caused a stop in February 2026, repeated SCADA warnings in July and August 2026, and a performance drop with stops and limitation.
The client rated Kavaken's role in the resolution as key.
- Production
- 40 MWh
- Financial
- USD 3,000
- CO2
- 20 t
Avoided-loss potential: Kavaken's estimate of the loss that the early finding prevented. It is not a realized saving.
Takeaway
A slow rise in main bearing temperature can stay under fixed SCADA and CMS limits for months. Track it against conditions such as the nacelle air temperature, and plan the inspection and parts before warnings, stops and limitation arrive.