On 9 August 2025 Kavaken flagged three gearbox temperatures on a wind turbine: a generator-side bearing, the sump oil and the gear inlet oil. They ran 10.2% above the expected range and 5.8% above the average of similar turbines on site, with a rising trend. The values stayed far below the 70 °C warning limit, so nothing in the alarms forced action. An oil additive and a filter replacement did not stop the trend. On 30 October 2025 Kavaken pointed to the thermal bypass valve. The site team replaced it on 5 August 2026, and the inlet and sump oil temperatures improved from that day.

Hotter than its peers, far from the limit
In February 2026 the site team checked the flagged temperature against the turbine's own parameters.
By the turbine's own limits, the temperature was acceptable. Compared with its peers and with its expected range, it was not. Kavaken's flag came from that second comparison.
369 days, step by step
KavakenSite team
- Day 0 · 9 Aug 2025 · Kavaken
Three gearbox temperatures run above expected
Kavaken flagged the generator-side gearbox bearing temperature and the sump and gear inlet oil temperatures. They ran 10.2% above the expected range and 5.8% above the average of similar turbines on site, with a rising trend. Kavaken recommended checking the gearbox oil and filters and reviewing the cooling system.
- Day 2 · 11 Aug 2025 · Site team · Fix 1 of 3
Oil foaming found, additive added
During maintenance the site team found foaming in the gearbox oil and added an additive to the oil.
Flag log, site team (translated): Foaming was found in the oil during maintenance. An additive has been added to the oil.
- Day 82 · 30 Oct 2025 · Kavaken
Kavaken points to the thermal bypass valve
The anomaly trend kept progressing. Kavaken recommended a check of the gearbox thermal bypass valve, and a replacement if needed.
Flag log, Kavaken (translated): The anomaly trend continues to progress. A check of the gearbox thermal bypass valve is recommended. If necessary, replacement of the thermal bypass is recommended.
- Day 157 · 13 Jan 2026 · Site team
Site confirms hotter oil in SCADA trends
On 7 January Kavaken reported that the signals fluctuated but the anomaly trend still pointed up. The site team compared SCADA trends with reference turbines, found the gearbox oil temperature higher and planned checks for when the weather allowed.
- Day 191 · 16 Feb 2026 · Kavaken
Anomaly spreads to rotor-side bearing temperatures
On 3 February Kavaken raised the flag to risk level 2 as the gear inlet oil temperature anomaly progressed. On 16 February the anomaly also showed in the rotor-side bearing temperatures. Kavaken recommended checking the thermal bypass valve first, then the gearbox lubrication and cooling system in general.
- Day 192 · 17 Feb 2026 · Site team
Values confirmed high, but below limits
The site team confirmed the temperature ran higher than on the other turbines on site. The warning value is 70 °C and the stop value 75 °C. The February maximum was 54.9 °C.
Flag log, site team (translated): It has been confirmed that the temperature runs higher than on the other turbines on site. The parameters show a Warn value of 70 °C and a Stop value of 75 °C.
- Day 247 · 13 Apr 2026 · Site team · Fix 2 of 3
Filter replaced, cooling system checked
As part of scheduled maintenance, the site team replaced the gearbox filter and checked the cooling system.
- Day 333 · 8 Jul 2026 · Kavaken
Kavaken names the likely root cause
Kavaken again recommended a thermal bypass valve check. A bypass that sends the oil past the cooling system all the time could be the root cause of the oil heating.
- Day 361 · 5 Aug 2026 · Site team · Fix 3 of 3
Thermal bypass valve replaced
On 4 August a high sump oil temperature warning was active for 7.75 hours, without a stop. The next day the site team replaced the gearbox thermal bypass valve.
- Day 369 · 13 Aug 2026 · Kavaken
Oil temperatures improve, flag closed
Kavaken confirmed a clear positive effect on the inlet and sump oil temperatures from the day of the replacement. The site team closed the flag as solved by the bypass valve replacement.
Flag log, Kavaken (translated): The positive effect of the thermal bypass replacement on the inlet and sump oil temperature is clearly visible from the day of the replacement. The intervention is successful, you can close the flag.
Why it stayed hidden
The temperatures rose slowly and stayed well inside the turbine's own limits. In February 2026 the peak was 54.9 °C against a 70 °C warning value, so no alarm fired. The deviation only showed against the expected range and against similar turbines on site. The first high sump oil temperature warning came on 4 August 2026, 360 days after the flag and one day before the valve was replaced.
The outcome
After the thermal bypass valve was replaced on 5 August 2026, Kavaken saw a clear positive effect on the gear inlet and sump oil temperatures from that day. The site team closed the flag on 13 August 2026, stating that the bypass valve replacement solved the problem.
The two earlier interventions, an oil additive after foaming was found and a gearbox filter replacement with a cooling system check, did not stop the rising trend. A bypass that constantly sent the oil past the cooling system was the likely root cause.
The client rated Kavaken's role in the resolution as key.
- Production
- 1,400 MWh
- Financial
- USD 106,500
- CO2
- 880 t
Avoided-loss potential: Kavaken's estimate of the loss that the early finding prevented. It is not a realized saving.
Takeaway
A gearbox running hotter than its peers but far below its warning limit can still have a cooling fault. If oil and filter work does not stop the trend, check whether the thermal bypass valve is sending the oil past the cooler.