    An oil pressure step that ended with a spalled high-speed shaft bearing

    Gearbox oil inlet pressure stepped up by 31.8% above its expected value and held the new level. Speed was stable and temperatures were falling, so the operating conditions did not explain it. The site team replaced the gearbox high-speed shaft, and the removed bearing ring showed heavy spalling.

    Wind520MWhavoided-loss potential
    +31.8%
    step above expected pressure, 29 Sep
    +93.8%
    above comparable turbines on the flag date
    3 stops
    on low oil inlet pressure, 5 Oct
    12 days
    from the flag to the completed HSS replacement

    Kavaken flagged a turbine whose gearbox oil inlet pressure had jumped on 29 September 2026, from 4.6% to 31.8% above its expected value, and stayed there. On the flag date it was 41.0% above expected and 93.8% above comparable turbines on the same farm. Kavaken asked whether a setpoint change or a part replacement explained the step, and recommended oil circuit checks. The next day the site team planned a gearbox high-speed shaft (HSS) replacement. On 5 October the turbine stopped three times on low oil inlet pressure. The replacement was carried out from 13 to 15 October, and the bearing ring that came out was heavily spalled.

    High pressure first, low-pressure stops after

    The same signal pointed in two directions within a week.

    Flagged by Kavaken
    +41.0%
    Oil inlet pressure above its expected value on 3 October, after a step change on 29 September that held.
    Turbine stops
    3 stops
    On 5 October the turbine stopped three times on low gearbox oil inlet pressure, for 1.3 hours and 178 kWh in total.

    The deviation was measured against the turbine's own model and against comparable turbines. Over the 14 days before the flag, power output rose by 22.5% while generator speed stayed stable, nacelle air temperature fell by 20.8% and ambient temperature fell by 38.5%. The pressure was above what those conditions predicted.

    Line chart of gearbox oil inlet pressure in bar with a shaded expected band and red out-of-band points, a dashed flag marker at early October, and a scatter plot of pressure against pitch angle.
    Figure 1. Gearbox oil inlet pressure from 45 days before the flag to 27 November 2026: a peak near 3.5 bar at the flag, then many days outside the expected band in October. Right: pressure against blade 2 pitch angle over 364 paired days.

    34 days, step by step

    SignalKavakenSite team

    1. Day −4 · 29 Sep 2026 · Signal

      Oil inlet pressure steps up and holds

      The deviation of gearbox oil inlet pressure versus its expected value rose from an average of 4.6% to 31.8%. Versus comparable turbines it rose from 3.5% to 31.1%. The new level was maintained.

    2. Day 0 · 3 Oct 2026 · Kavaken

      Kavaken flags overpressure in the oil circuit

      On the flag date the pressure was 41.0% above expected and 93.8% above comparable turbines. Kavaken recommended inspecting the oil filter for blockage and metallic particles, verifying the pressure with a calibrated gauge and testing the pressure regulating valve and the circulation pump line.

      Flag log, Kavaken (translated): Please check whether this sudden change is due to a known wind farm-related cause, such as a parameter/setpoint revision or equipment replacement.

    3. Day 1 · 4 Oct 2026 · Site team

      Site team plans an HSS replacement

      The site team set the gearbox high-speed shaft replacement for the week of 12 October.

      Flag log, site team (translated): The gearbox HSS replacement will be done in the week of 12 October.

    4. Day 2 · 5 Oct 2026 · Signal

      Three stops on low oil inlet pressure

      The turbine stopped three times on low gearbox oil inlet pressure, for 39, 28 and 9 minutes. Together the stops lasted 1.3 hours and cost 178 kWh.

      Event table listing three low oil inlet pressure stops on 5 October 2026 with their durations and energy losses, above summary tiles for stop time and stop loss.
      Figure 2. Three stops on low gearbox oil inlet pressure on 5 October 2026: 39, 28 and 9 minutes, 1.3 hours and 178 kWh in total.
    5. Day 10 to 12 · 13 Oct – 15 Oct 2026 · Site team · Fix

      Gearbox high-speed shaft replaced

      The site team carried out the HSS replacement over three days. The inner bearing ring removed in the work shows heavy spalling across its raceway.

      Flag log, site team (translated): The HSS replacement started on 13.10.2026. The work was completed on 15.10.2026.

      A gloved hand holding a bearing inner ring whose raceway surface is heavily pitted and flaked, on a metal floor plate next to a shaft end.
      Figure 3. The inner bearing ring removed during the high-speed shaft replacement, with heavy spalling across the raceway.
    6. Day 19 · 22 Oct 2026 · Site team

      Site team reports the work complete

      The site team confirmed the replacement as completed.

      Flag log, site team (translated): HSS replacement completed.

    7. Day 33 · 5 Nov 2026 · Kavaken

      Kavaken asks for dates and bearing photos

      Kavaken asked the site team for the replacement date and for photos of the bearings.

    8. Day 34 · 6 Nov 2026 · Site team

      Photos shared and the flag resolved

      The site team shared photos of the removed bearing ring and of the assembly after the work. The flag was resolved.

      Flag log, site team (translated): The state after the work was completed was shared.

    The outcome

    The site team completed the gearbox high-speed shaft replacement on 15 October 2026 and documented it with photos: the spalled inner bearing ring that was removed, and the rollers and cage in the housing after the work. The flag was resolved on 6 November 2026.

    Kavaken's analysis had pointed to the pressure regulating valve in the oil inlet circuit as the most likely cause. The work carried out was the HSS replacement. How the bearing damage relates to the pressure step was not established.

    The client rated Kavaken's role in the resolution as key.

    Close-up of cylindrical rollers seated in a brass cage inside a gearbox bearing housing, lit by a bright work lamp.
    Figure 4. Rollers in their cage inside the housing after the replacement was completed.
    Production
    520 MWh
    Financial
    USD 34,500
    CO2
    330 t

    Avoided-loss potential: Kavaken's estimate of the loss that the early finding prevented. It is not a realized saving.

    Takeaway

    When a pressure signal steps up and holds the new level, ask the same week whether a setpoint or a part changed. If nothing did, treat it as a hardware finding and plan the inspection before the turbine starts stopping on it.

    Next caseHot gearbox oil: the bypass valve flagged in October fixed it in AugustRead the case →
    Kavaken

    Autonomous Asset Performance Managementfor Renewable Energy

    Monthly updates from Kavaken. Unsubscribe anytime.

    United Kingdom

    Kavaken Limited

    TUSPark Eagle Labs
    27 Grainger Street
    Newcastle, NE1 5JE

    United States

    Kavaken, Inc.

    2500 Yale St Ste B
    Houston, TX 77008

    Türkiye

    Kavaken Yazılım A.Ş.

    Resitpasa Mah. Katar Cad.
    ITU ARI 8, 2/11
    Istanbul, 34467

    Member of:
    ORE CatapultNOFGWECTÜREBAmerican Clean Power
    Find us at:
    LinkedInYouTube

    © 2026 Kavaken. All rights reserved.