Kavaken flagged the rotor-end main shaft bearing temperature on a wind turbine. It was running 25% above the expected range and above the average of similar turbines on the site. The deviation was steady and the risk was rated low, with a rising trend. The OEM took the issue into planned maintenance, ran a borescope inspection, and the main bearing and generator were replaced. After the swap, the bearing looked normal against its own history. Against the site's other turbines, it was still running hotter. Kavaken kept flagging that gap. On that flag, the OEM decided on a lube oil flushing and applied it, and the client closed the flag after an observation period.
Two baselines, two answers
After the main bearing and generator replacement, Kavaken checked the bearing signals against two references.
A new component resets its own baseline, so a check against its own history alone would have shown nothing. The fleet comparison kept the issue open and led to the flushing.
327 days, step by step
KavakenOEMSite team
- Day 0 · 21 Jun 2025 · Kavaken
Rotor-end bearing runs 25% above expected
Kavaken flagged the main shaft bearing temperature at the rotor end. It ran 25% above the expected range and above the average of similar turbines on the site. The deviation was consistent, the risk low and the trend rising. The common procedure for such a flag is to check the lubrication parameters, lubricate more often if needed, and flush if that does not help.

Figure 1. Main shaft bearing temperature at the rotor end from 45 days before the flag, with flagged readings marked from July to October 2025, and the same temperature plotted against ambient air temperature over 551 paired days. - Day 137 · 5 Nov 2025 · OEM
OEM adds the check to planned maintenance
The OEM took the issue into its planned maintenance and scheduled borescope measurements. A team was planned on site for 12 and 13 November.
Flag log, site team (translated): The OEM took it into its planned maintenance and will carry out borescope measurements soon.
- Day 144 · 12 Nov 2025 · OEM
Borescope inspection carried out
Borescope measurements were taken on the main bearing. The decision that followed was a replacement of the main bearing and the generator.
- Day 164 to 173 · 2 Dec – 11 Dec 2025 · OEM · Fix
Main bearing and generator replaced
The main bearing and generator replacement started on 2 December and was completed on 11 December. The flag moved into an observation period to follow the values after the swap.
Flag log, site team (translated): The main bearing and generator replacement was completed on 11.12.2025.
- Day 179 · 17 Dec 2025 · Kavaken
Gap to the fleet remains after replacement
Compared with its own history, the anomaly was gone. Compared with the site's turbines, the bearing still diverged. Kavaken kept the gap under watch.
Flag log, Kavaken (translated): Looking at the main bearing signals after the replacement, the anomaly has disappeared compared with its own history, but the divergence from the turbines on site continues. The divergence from the site turbines should be followed for a while.
- Day 215 · 22 Jan 2026 · Kavaken
Gap to site average trends upward
Kavaken saw the divergence from the site average growing, not fading.
- Day 285 · 2 Apr 2026 · Site team
Observation period checked, fault resolved
The client checked the observation period, recorded the fault as resolved and closed the flag.
- Day 327 · 14 May 2026 · Site team
Flushing applied on the Kavaken flag
The site reported that the OEM had applied a lube oil flushing. The OEM made that decision after the Kavaken flag showed the temperature still above the site average. Flushing was the action Kavaken had recommended from the start.
Flag log, site team (translated): After the bearing replacement, the Kavaken flag indicated that the temperature was still running above the site average. On that, the OEM was contacted, and the OEM decided on flushing and applied it.
Why it stayed hidden
The deviation was consistent and the risk was rated low, so nothing forced an urgent stop. After the replacement, the bearing's own readings no longer showed an anomaly, because the new part started a new history. Only the comparison with the site's similar turbines showed that the bearing was still running hotter, and that the gap was growing.
The outcome
After the main bearing and generator replacement, the anomaly disappeared against the bearing's own history. The temperature still ran above the site average, and in January 2026 that gap was trending upward.
The OEM then decided on a lube oil flushing because of the Kavaken flag, and applied it. The client checked the observation period, recorded the fault as resolved and closed the flag.
The client rated Kavaken's role in the resolution as key.
- Production
- 450 MWh
- Financial
- USD 34,100
- CO2
- 280 t
Avoided-loss potential: Kavaken's estimate of the loss that the early finding prevented. It is not a realized saving.
Takeaway
After a major component swap, compare the new part with the rest of the fleet, not only with its own history. A fresh baseline can look clean while the gap to similar turbines keeps growing.