Customer stories / Gearbox oil system / Failure risk

    A clean borescope, then the bypass valve named in the first flag

    Gearbox sump oil ran a few percent warm on one turbine, rated low risk but rising. A borescope made on a separate CMS ticket found nothing. Reversing the thermal bypass valve so the oil always passes the radiator brought the temperature back below the anomaly threshold.

    Wind720MWhavoided-loss potential
    +3.2%
    sump oil above expected range
    +8.4%
    above similar turbines in the farm
    170 days
    from flag to the valve fix

    On 31 January 2026 Kavaken flagged the gearbox sump oil temperature of one wind turbine: 3.2% above its expected range and 8.4% above the average of similar turbines in the farm, with an upward trend. The risk was low, and the first recommendation was to check the gearbox thermal bypass valve. A gearbox borescope in April, made on a CMS ticket, found no anomaly. Kavaken repeated the bypass recommendation in June. On 20 July the site team reversed the thermal bypass valve so the oil flows through the radiator at all times. By 9 August the anomaly on the gearbox inlet and sump oil temperatures had fallen below the threshold.

    Line chart of gearbox oil inlet temperature in °C with a green expected band, a dashed flag line in late January and red anomaly points in June, July, October and November; beside it a scatter plot against pitch motor current.
    Figure 1. Gearbox oil inlet temperature against its expected band from 45 days before the flag to 27 November 2026, with anomalous days marked in red, and its relation to pitch motor current over 376 paired days.

    Two checks, two answers

    Two different checks were made on the same warm gearbox.

    Gearbox borescope, 29 April 2026
    No anomaly
    Made on a CMS ticket. The site team saw no anomaly in the gearbox after the inspection.
    Thermal bypass valve, 20 July 2026
    Below threshold
    Kavaken recommended this check on day one and again in June. After the valve was reversed, the oil temperature anomaly fell below the threshold.

    The borescope ruled out visible damage inside the gearbox. The warm oil was a cooling path question, which is where the flag had pointed from the start.

    194 days, step by step

    KavakenSite teamSignal

    1. Day 0 · 31 Jan 2026 · Kavaken

      Sump oil runs warm, check bypass valve

      Kavaken flagged the gearbox sump oil temperature at 3.2% above the expected range and 8.4% above the average of similar turbines in the farm. Risk was low, the trend was rising. The first recommendation was to check the gearbox thermal bypass valve.

    2. Day 88 · 29 Apr 2026 · Site team

      Gearbox borescope finds no anomaly

      The site team made a gearbox borescope inspection, triggered by a CMS ticket. No anomaly was found.

      Flag log, site team (translated): No anomaly was seen after the borescope. The borescope was done on a CMS ticket.

    3. Day 92 · 3 May 2026 · Signal

      Bypass filter warning runs 88.6 hours

      A gearbox bypass filter replacement warning was active for 88.64 hours. It caused no stop and no recorded production loss.

    4. Day 130 · 10 Jun 2026 · Kavaken

      Kavaken repeats the bypass valve check

      Kavaken explained that a rise in gearbox inlet and sump oil temperature usually comes from a thermal bypass system that does not work effectively, and recommended checking it.

      Flag log, Kavaken (translated): The rising gearbox inlet and sump oil temperature anomaly is usually caused by the thermo bypass system not working effectively. A check is recommended.

    5. Day 159 · 9 Jul 2026 · Site team

      Parts ordered to renew the bypass system

      The site team planned maintenance and ordered material to renew the thermal bypass system.

      Flag log, site team (translated): The order has been placed. When the material arrives, the thermo bypass system will be renewed.

    6. Day 170 · 20 Jul 2026 · Site team · Fix

      Bypass valve reversed, oil always cooled

      The site team reversed the thermal bypass valve so the oil flows through the radiator at all times. The flag moved to an observation period.

      Flag log, site team (translated): The thermo bypass valve was reversed, continuous flow to the radiator was ensured. 20/7/2026

    7. Day 190 · 9 Aug 2026 · Kavaken

      Anomaly falls below the threshold

      Kavaken reported that the anomaly on both gearbox oil signals, gear inlet and sump temperature, had fallen below the threshold, and asked the client to close the flag if no further work was needed.

    8. Day 194 · 13 Aug 2026 · Site team

      Flag resolved

      The flag was closed as resolved, 194 days after detection.

    Why it stayed hidden

    +3.2%
    above the expected range at detection
    Low
    risk rating of the deviation
    0 h
    of stops during the bypass filter warning

    The sump oil was only a few percent warmer than expected, and the deviation was rated low risk. The turbine kept running: a bypass filter warning in May was active for 88.64 hours without a single stop or recorded loss. A borescope made on a separate CMS ticket found nothing inside the gearbox. Nothing on site pointed to the cooling path except the comparison with the turbine's own expected range and with similar turbines in the farm.

    The outcome

    After the thermal bypass valve was reversed on 20 July 2026, Kavaken observed both gearbox oil signals, gear inlet and sump temperature, and on 9 August reported that the anomaly had fallen below the threshold. The flag was resolved on 13 August 2026. The client rated Kavaken's role in the resolution as key.

    Before the valve was reversed, the site team had ordered material to renew the thermal bypass system. The product chart later shows the gearbox oil inlet temperature above the expected band again on a few days in October and November 2026.

    Production
    720 MWh
    Financial
    USD 45,900
    CO2
    450 t

    Avoided-loss potential: Kavaken's estimate of the loss that the early finding prevented. It is not a realized saving.

    Takeaway

    When gearbox oil runs warm and an internal inspection finds nothing, check the thermal bypass valve. A valve that does not send oil through the radiator keeps the oil warm while the gearbox itself looks healthy.

    Next caseA bearing lubricant fix on one flagged turbine, reused on two moreRead the case →
    Kavaken

    Autonomous Asset Performance Managementfor Renewable Energy

    Monthly updates from Kavaken. Unsubscribe anytime.

    United Kingdom

    Kavaken Limited

    TUSPark Eagle Labs
    27 Grainger Street
    Newcastle, NE1 5JE

    United States

    Kavaken, Inc.

    2500 Yale St Ste B
    Houston, TX 77008

    Türkiye

    Kavaken Yazılım A.Ş.

    Resitpasa Mah. Katar Cad.
    ITU ARI 8, 2/11
    Istanbul, 34467

    Member of:
    ORE CatapultNOFGWECTÜREBAmerican Clean Power
    Find us at:
    LinkedInYouTube

    © 2026 Kavaken. All rights reserved.