Customer stories / Generator bearing (NDE) / Failure risk

    A bearing lubricant fix on one flagged turbine, reused on two more

    A generator bearing ran 48.3% above its expected temperature range, but the deviation was steady and rated low risk. A week after the flag, the site team added a special lubricant. The anomaly cleared, and the site used the same fix on two more turbines.

    Wind450MWhavoided-loss potential
    +48.3%
    above the expected range
    +84.1%
    above similar turbines on the farm
    7 days
    from flag to lubricant
    2
    more turbines given the same fix

    On 8 May 2026 Kavaken flagged the non-drive-end bearing of a generator at a client's wind farm. Its temperature ran 48.3% above the expected range and 84.1% above the average of similar turbines on the farm. The deviation was steady and rated low risk, with a rising trend, so nothing forced a stop. Kavaken recommended cleaning the bearing greasers and checking the automatic lubrication. On 15 May the site team brought in a special lubricant and added it. By 12 June the temperature anomaly was gone. The site then used the same lubricant on two more turbines that had the same kind of flag.

    Two charts. Left: daily generator non-drive-end bearing temperature with a shaded expected band, a red flag line in early May and red dots for anomalous days. Right: bearing temperature plotted against generator rotational speed, coloured from older to newer days.
    Figure 1. Generator non-drive-end bearing temperature against its expected band from late March to late November 2026, with the flag in early May. The right panel plots the temperature against generator speed.

    The same fix, two more turbines

    After the result on this turbine, the site ordered the same lubricant for two other turbines on the farm. Both carried the same kind of generator bearing flag.

    On one of them, an earlier cleaning had not brought the temperature down. After the lubricant change, the temperature returned to normal. On the other, the temperature dropped after the change.

    One Kavaken flag led to a fix that the site then applied on two more turbines.

    35 days, step by step

    KavakenSite team

    1. Day 0 · 8 May 2026 · Kavaken

      Kavaken flags the generator NDE bearing

      The non-drive-end generator bearing temperature ran 48.3% above the expected range and 84.1% above the average of similar turbines on the farm. The deviation was consistent and rated low risk, with an upward trend. Kavaken recommended cleaning the bearing greasers and checking the automatic lubrication mechanism.

    2. Day 7 · 15 May 2026 · Site team · Fix

      Special lubricant added to the bearing

      The site team brought in a special lubricant and added it. The flag moved into an observation period so that the bearing temperature could be checked again afterwards.

      Flag log, site team (translated): On 15.05.2026 a special oil was brought in and added. It will be checked again after the observation period.

    3. Day 7 to 35 · 15 May – 12 Jun 2026 · Kavaken

      Bearing temperature under observation

      Kavaken watched the bearing temperature against its expected range to see whether the lubricant had an effect.

    4. Day 35 · 12 Jun 2026 · Kavaken

      Temperature anomaly no longer visible

      Kavaken's review found that the temperature anomaly had disappeared. The intervention was judged successful, and the flag was ready to close.

      Flag log, Kavaken (translated): The temperature anomaly is seen to have disappeared. The intervention is successful; the flag can be closed.

    5. Day 35 · 12 Jun 2026 · Site team

      Resolved, temperatures back to normal

      The site team confirmed the result and resolved the flag.

      Flag log, site team (translated): The work gave a positive result; the temperature values have returned to normal.

    The outcome

    The result was confirmed on 12 June 2026, after the observation period. Kavaken's review showed that the temperature anomaly had disappeared, and the site team reported that the temperature values had returned to normal. The client rated Kavaken's role as helpful.

    The longer product chart, which runs to late November 2026, still shows a few isolated readings above the expected band in the months after the fix.

    The site then applied the same lubricant to two more turbines with the same kind of generator bearing flag.

    Production
    450 MWh
    Financial
    USD 26,000
    CO2
    280 t

    Avoided-loss potential: Kavaken's estimate of the loss that the early finding prevented. It is not a realized saving.

    Takeaway

    A steady, low-risk bearing temperature deviation can still point to a lubrication problem worth fixing. When one fix works, check whether other turbines with the same flag on the farm can take the same fix.

    Next caseTransformer winding heat rose as load fell; new fans and fuse ended itRead the case →
    Kavaken

    Autonomous Asset Performance Managementfor Renewable Energy

    Monthly updates from Kavaken. Unsubscribe anytime.

    United Kingdom

    Kavaken Limited

    TUSPark Eagle Labs
    27 Grainger Street
    Newcastle, NE1 5JE

    United States

    Kavaken, Inc.

    2500 Yale St Ste B
    Houston, TX 77008

    Türkiye

    Kavaken Yazılım A.Ş.

    Resitpasa Mah. Katar Cad.
    ITU ARI 8, 2/11
    Istanbul, 34467

    Member of:
    ORE CatapultNOFGWECTÜREBAmerican Clean Power
    Find us at:
    LinkedInYouTube

    © 2026 Kavaken. All rights reserved.