On 18 September 2025, Kavaken flagged the generator non-drive-end bearing temperature of a wind turbine. It was running 15.5% above its expected range and 23.5% above the average of similar turbines in the wind farm. The deviation was steady, and the trend was upward. Nothing forced action: SCADA gave no warning, and by SCADA the temperatures were normal. After the flag, a visit to the turbine showed that the bearing needed flushing. The OEM carried out the flushing on 10 February 2026, and the positive effects showed in the signals the next day.
What similar cases pointed to
In similar cases on the same turbine type, the most common procedure was to clean the lubrication channels of the bearings, the chimneys and the waste oil reservoir.
Kavaken recommended two actions: check the automatic lubrication mechanism and maintain it if needed, and flush the bearing. Flushing was the work that resolved the case.
146 days, step by step
KavakenSite teamOEM
- Day 0 · 18 Sep 2025 · Kavaken
Kavaken flags overheating in the generator NDE bearing.
The generator non-drive-end bearing temperature was 15.5% above its expected range and 23.5% above the average of similar turbines in the wind farm. The deviation was consistent, and the trend was upward. Kavaken recommended a check of the automatic lubrication mechanism and a bearing flushing.
- Day 77 · 4 Dec 2025 · Site team
The site team asks the OEM to inspect.
The client opened the investigation and passed the flag to the OEM for inspection.
Flag log, site team (translated): The OEM was informed so that it could inspect the issue.
- Day 145 · 10 Feb 2026 · OEM · Fix
The OEM flushes the bearing.
After the Kavaken flag, a visit to the turbine showed that flushing was needed. The OEM carried out the flushing and completed its checks.
Flag log, site team (translated): Flushing was carried out by the OEM, and the checks were completed.
- Day 146 · 11 Feb 2026 · Site team
The signals show the effect, and the flag is resolved.
The day after the flushing, the site team saw the positive effects of the intervention in the signals and resolved the flag.
Flag log, site team (translated): The positive effects of the intervention were seen in the signals.
Why it stayed hidden
SCADA raised no warning, and by SCADA the bearing temperatures were at normal levels. The deviation only stood out against the bearing's expected range and against similar turbines in the same wind farm. A steady, rising deviation that stays inside the alarm limits does not trigger an alarm. According to the client, the turbine visit that found the need for flushing was made because of the Kavaken flag.
The outcome
The OEM flushed the bearing on 10 February 2026 and completed its checks. The next day, the site team saw the positive effects of the intervention in the signals and resolved the flag.
In the months after the flushing, the chart shows the bearing temperature moving inside its expected band, without the readings that were marked above it in late 2025.
The client rated Kavaken's role as helpful.

- Production
- 160 MWh
- Financial
- USD 10,500
- CO2
- 100 t
Avoided-loss potential: Kavaken's estimate of the loss that the early finding prevented. It is not a realized saving.
Takeaway
A bearing temperature that is within SCADA limits can still be well above where it should run. Compare it with an expected range and with similar turbines on the same farm, and check lubrication before the limit is reached.